Category 05

Flat-Pack Container House

Factory-prepared roof and base frame assemblies with welded corner fittings, configurable wall panels and glazing. Suitable for site offices, worker accommodation, retail and commercial configurations. Final dimensions and panel specification per approved drawings.

Flat-pack configuration reference
Click to enlarge

Nominal Dimensions

External reference dimensions. Final project configuration per approved drawings.

6.055 m
Nominal Length
External reference dimension
2.99 m
Nominal Width
External reference dimension
2.896 m
Nominal Height
External reference dimension

Applications

Typical uses. Final layout and configuration per approved drawings.

Site Office & Reception

The full-width glazed frontage configuration is well suited to site offices, reception counters and security checkpoints. Internal layout and partition positions are confirmed per project.

Worker Accommodation

Units can be arranged in single or multi-storey rows for workforce accommodation. Multi-storey configurations require project-specific structural engineering and are not a guaranteed standard capacity.

Café & Retail

The modular form supports commercial configurations including cafés, retail kiosks and pop-up venues. The two-storey example shown is a specific project configuration, not a standard product.

Interior Fit-Out Reference

The clean white-panel interior with grey floor finish illustrates a typical base fit-out. Interior linings, flooring and MEP are confirmed per order.

Colours & Finishes

Select a wall-panel colour option. Configuration photograph; colour swatch is a finish reference. Confirm final colour and texture against agreed samples.

Configuration photograph — Selected wall-panel colour: Cream White

Neutrals

Colours

Wood-Look

Structure & Components

Factory-welded frame assemblies distinguish the flat-pack from bolted quick-assembly products.

Welded Roof & Base Frame Assemblies

The roof and base frames are factory-welded steel assemblies with corner fittings integrated at the factory. This distinguishes the flat-pack from quick-assembly products where corner fittings are bolted on site. Final site connections are made per the approved assembly drawings.

Corner Columns & Structural Profiles

Formed steel corner columns and structural profiles carry vertical and lateral loads. Profile dimensions, wall thickness and surface treatment are specified per approved drawing.

Corner Joint Detail

The welded corner fitting provides the primary structural connection between roof frame, base frame and corner columns. Connection geometry and weld specification are confirmed in the approved drawings.

Materials & Configuration

Materials options and specifications confirmed per order.

ComponentSpecification
Primary structureWelded steel roof and base frame assemblies with integrated corner fittings; profile, thickness and surface treatment per approved drawing
Corner columnsFormed steel corner columns; profile and thickness per approved drawing. Corner fittings are welded into the factory frame assemblies — not bolted on site
Wall panels50 mm / 75 mm / 100 mm composite sandwich panel — rock wool or polyurethane core (subject to order)
RoofRoof assembly options include profiled steel roof sheets, insulation layer and ceiling lining sheets; specific build-up, slope, drainage and weatherproofing details confirmed per project specification
FloorSteel deck with floor decking (e.g. 18 mm sanded cement board); floor finish applied separately; support spacing and load rating per approved assembly drawings
Exterior finishColour-coated steel sheet; colour and texture options available on request — confirmed against agreed samples before production
DoorsSteel personnel door (standard); alternative door types available — scope confirmed at order stage
WindowsuPVC windows with security bars shown; other window configurations, glazing and sizes confirmed in the quotation
Interior liningPainted steel sheet (standard); plywood, PVC or other linings available on request
ElectricalBasic wiring and distribution board available as option; full MEP to project specification

Component & Accessory Reference

Structural Frame

Roof Frame Tubes

Steel hollow section tubes used in roof frame assemblies. Component-type reference — flat-pack profiles per approved drawings.

Frame Assembly Packing

Welded roof and base frame assemblies stacked for export. Packing method confirmed per order.

Corner Columns

Steel corner column profiles. Profile dimensions and surface treatment per approved drawing.

Corner Fittings (Welded)

Welded corner fittings integrated into factory frame assemblies. Component-type reference — geometry per approved drawings.

Floor Frame Tubes

Steel hollow section tubes used in the floor frame assembly. Component-type reference — spacing and load rating per approved drawing.

Top Side Beams

Top side beam members forming the upper perimeter of the frame. Component-type reference — dimensions per approved drawing.

Top End Beams

Top end beam members. Component-type reference — profile and surface treatment per approved drawing.

Panels, Insulation & Flooring

Rock Wool Sandwich Panel

Rock wool core sandwich panel for walls. Panel thickness confirmed per order. Component-type reference.

Glass Wool Insulation

Glass wool insulation rolls used in wall and roof assemblies. Density and thickness per thermal specification.

Roof Sheets

Profiled steel roof sheets. Profile, coating and thickness per specification.

Ceiling Lining Sheets

Profiled steel ceiling lining sheets. Profile and finish per specification.

Cement Board (18 mm)

Sanded cement board used as floor decking substrate. Thickness and load rating per approved drawing.

Trims & Connections

Aluminium Angle Trim

Aluminium angle trim used at panel joints and perimeter edges. Profile and finish per specification.

Panel Retaining Channels

Steel channels used to retain and align wall panels at top and bottom. Profile per approved drawing.

Doors & Windows

Steel Security Door

Steel personnel door with frame and hardware. Door type and security rating confirmed per order.

uPVC Window

uPVC window with security bars. Window size, glazing and configuration confirmed in the quotation.

Factory & Production

Charcoal-frame glazed cabin under workshop overhead crane — factory handling reference.
Welded roof and base frame assemblies stacked for packing — factory storage reference.

Shipping & Installation

Packing, loading plans, installation scope and documentation are agreed for each order.

01

Frame Assembly Packing

Welded roof and base frame assemblies, corner columns and wall panels are packed flat for export. Packing method, container loading plan and shipping documentation are agreed for each order.

02

Workshop Handling & Dispatch

Overhead crane handling is used in the workshop for safe movement of frame assemblies. Export packing and loading are coordinated with the agreed freight forwarder.

03

Foundation & Site Preparation

Site foundations or a prepared base are required before assembly. Foundation type — concrete pads, ground beams or raised supports — depends on ground conditions and local requirements. Foundation design and scope are agreed per order.

04

Assembly & Fit-Out

Frame assemblies are erected on the prepared base, wall panels and glazing installed, and interior fit-out completed. Required assembly documentation and any installation support are agreed before dispatch.

Frequently Asked Questions

What are the nominal dimensions?+
The nominal external reference dimensions are approximately 6.055 m length × 2.99 m width × 2.896 m height. These differ from our quick-assembly product (approx. 5.95 m × 3.0 m × 2.8 m). Final dimensions for your project are confirmed in the approved drawings.
How does this differ from the quick-assembly product?+
The flat-pack uses factory-welded corner fittings integrated into the roof and base frame assemblies. The quick-assembly product uses bolted corner fittings assembled on site. The two products have different nominal dimensions and structural details — they are not interchangeable.
Can dimensions and finishes be customised?+
Yes. Width, length, height, wall panel thickness, insulation type, exterior colour, door and window positions, and interior finishes can all be specified. Please provide your requirements when requesting a quote.
Can units be stacked to two storeys?+
Multi-storey configurations are possible for some applications, but require project-specific structural engineering. Stacking capacity is not a guaranteed standard feature — it must be confirmed by a structural engineer for each project.
Does the building require foundations?+
Yes. The appropriate foundation type depends on your ground conditions, local loading requirements and intended use. Your structural engineer or local authority should confirm the foundation design. We supply base-plate and connection details to support your site preparation.
What information do you need to provide a quote?+
Destination port or delivery address; intended use and occupancy; quantity of units; preferred dimensions or layout drawing; wall panel thickness and insulation preference; door, window and interior finish requirements; any applicable local standards. The more detail you share, the more precise our quotation.

Enquire About the Flat-Pack Container House

Share your project requirements and we will prepare a tailored quotation.

Selected colour: Cream White